Offering you a complete choice of products which include fcm 1 notifier control module, notifier fmm-1 addressable monitor module - lixon power project, honeywell morley mi-dmmie input module, cooper (eaton) mcom addressable output module, notifier iso-x fault isolator module ul en-54 certified by lixon power project and simplex 4090-9116 addressable idnet communications isolator.
₹ 2200 / Piece Get Latest Price
| Control Module Type | Relay Control Module |
| Input Voltage | 24 V |
| Country of Origin | Made in India |
| Maximum Current (Relay Active) | ~5.5 mA @ 24 V DC (LED on) |
| Product Type | Addressable Control Module |
| Weight | Approx. 150 g |
| Certifications & Listings | UL Listed, FM Approved, CSFM, MEA Approved |
Brand: Notifier (by Honeywell)
Model No.: FCM-1
Product Type: Addressable Control Module
Operating Voltage Range: 15–32 V DC
Standby Current @ 24 V DC: ~340 µA (with LED blink on poll)
Maximum Current (Relay Active): ~5.5 mA @ 24 V DC (LED on)
Relay Ratings:
2 A @ 30 V DC (resistive load)
0.5 A @ 30 V DC (inductive load)
0.9 A @ 110 V AC (resistive load)
Function: Provides Form-C relay output to control fans, dampers, doors, and other auxiliary fire protection functions
Communication Protocol: FlashScan® (only)
Addressing: Rotary decimal addressing — point-addressable up to panel capacity
LED Indicators: Green blink when polled, red latch when activated
Mounting Options: Standard 4-inch square electrical box
Dimensions: ~4.5″ H × 4″ W × 1.3″ D (115 mm × 102 mm × 34 mm)
Weight: Approx. 150 g
Construction: Rugged plastic enclosure with plug-in terminals
Certifications & Listings: UL Listed, FM Approved, CSFM, MEA Approved
₹ 2400 / Piece Get Latest Price
| Loop Protocol | Notifier |
| Monitored Circuit | ADDRESABLE |
| Mounting Type | Wall Mounted |
| Phase | Dual Phase |
| Power Supply | 24 VDC |
| Brand | Honeywell Notifier |
| Display Type | Analog |
| Model Name/Number | FMM-1 |
| Operating Voltage | 15-32 V DC |
| Country of Origin | Made in India |
Brand: Notifier (by Honeywell)
Model No.: FMM-1
Product Type: Addressable Monitor Module
Operating Voltage Range: 15–32 V DC
Standby Current @ 24 V DC: ~375 µA (with LED blink on poll)
Maximum Alarm Current: ~5.5 mA @ 24 V DC (LED steady on)
Function: Monitors normally open (N.O.) contact devices such as pull stations, waterflow switches, or supervisory devices
Communication Protocol: FlashScan® (only)
Addressing: Rotary decimal addressing — point-addressable up to panel capacity
LED Indicators: Red LED — flashes when polled, steady on during alarm
Mounting Options: Standard 4-inch square electrical box
Dimensions: ~4.5″ H × 4″ W × 1.3″ D (115 mm × 102 mm × 34 mm)
Weight: Approx. 150 g
Construction: Plastic housing with plug-in terminal connections
Application: Ideal for monitoring sprinkler waterflow, supervisory switches, manual pull stations, and other contact devices
Certifications & Listings: UL Listed, FM Approved, CSFM, MEA Approved
₹ 2400 / Piece Get Latest Price
| Number of Channels | 2 |
| Power Supply | 24 VDC |
| Brand | Honeywell Morley MI-DMMIE |
| Humidity | 0% to 95% RH, non-condensing |
| Display Type | Analog |
| Model Name/Number | Morley MI-DMMIE |
| Dimensions Mm | 93 x 94 x 23 mm |
| Operating Temperature | -20 DegreeC to +60 DegreeC |
| Operating Voltage | 15-30 V DC |
| Phase | Dual Phase |
| Country of Origin | Made in India |
Brand: Honeywell Morley-IAS
Model No.: MI-DMMIE
Product Type: Addressable Mini Monitor Module (Single Input)
Operating Voltage Range: 15–30 V DC
Standby Current @ 24 V DC: ~310 µA (no communications); ~510 µA (with polling)
Function: Monitors one normally open (N.O.) dry contact device (e.g., pull station, supervisory switch)
Mounting Options: Surface box (M200E-SMB) or DIN-rail (M200E-DIN)
LED & Design Features: Tri-colour LED—green blink poll, red for alarm, yellow fault; visible LEDs & address switch on two sides; built-in short-circuit isolator; plug-in terminals
Dimensions: 93 × 94 × 23 mm
Weight: ~100 g
Operating Temperature Range: –20 °C to +60 °C
Humidity: 0% to 95% RH, non-condensing
Certifications & Listings: GEA GEI 1-082, CEA GEI 1-084
₹ 1650 / Piece Get Latest Price
| Number of Channels | 2 |
| Brand | Cooper (Eaton) |
| Phase | Single Phase |
| Power Supply | 24 VDC |
| Model Name/Number | Cooper (Eaton) MCOM Addressable Output Module |
| Dimensions Mm | ~63 x 35 x 18.5 mm |
| Operating Voltage | 18.5-30 V DC |
Brand: Cooper (Eaton)
Model No.: MCOM
Product Type: Addressable Single-Channel Output Module (Micro Interface)
Operating Voltage: 18.5–30 V DC
Quiescent (Standby) Current: ~310 µA
Output: Changeover relay (non-latching), suitable for low-voltage switching — typically 1 A max @ 24–30 V DC (up to ~30 W)
Addressing: Soft addressing / auto-configured by the system (no dip switches)
Short-Circuit Isolation: Integral isolator included (no external isolator required)
Variants:
MCOM-R — reset pulse output (for resetting beams)
MCOM-S — sounder-type behavior (resets on panel reset, not silence)
MCOM-FC — fan controller variant (different reset/behaviour logic)
Certifications: EN54-17 (short-circuit isolators) and EN54-18 (input/output devices) compliant
Construction: Compact PC/ABS enclosure
Dimensions (HxWxD): ~63 × 35 × 18.5 mm
Weight: ~78 g
Mounting & Wiring: Designed for quick installation; accepts single-strand cable up to 2.5 mm²; loop and output earth/ shield terminals provided
Applications: Activation of HVAC controls, fire door releases, notification appliances, plant shutdowns, beam resets and similar low-voltage control tasks
₹ 2300 / Piece Get Latest Price
| Phase | Single Phase |
| Power Supply | 24 VDC |
| Brand | Notifier ISO X Fault Isolator Module |
| Display Type | Analog |
| Model Name/Number | ISO X Fault Isolator Module |
| Product Type | Addressable Fault / Loop Isolator Module |
| Operating Voltage Range | 15 – 32 V DC |
| Certifications / Listings | UL (UOXX), ULC (for ISO-X(A)), FM Approved, CSFM, MEA |
Notifier ISO-X Fault Isolator Module
The Notifier ISO-X Fault Isolator Module is an essential device used in addressable fire alarm systems to protect the Signaling Line Circuit (SLC) from short circuits. When a short occurs, this module automatically isolates the affected section while allowing the rest of the loop to function normally, ensuring uninterrupted system operation and faster fault location.
This isolator is fully compatible with Notifier Onyx and CLIP series panels and is powered directly by the SLC loop, which means no external power supply is required. The built-in LED indicator flashes during normal operation and glows steady to signal a short circuit. Once the fault is cleared, the module automatically resets, restoring the loop to its standard condition.
The Notifier ISO-X module is engineered for easy installation inside a standard 4 inch square junction box (minimum 2.125 inch deep) and uses SEMS screw terminals for secure wiring. It supports wiring styles 4, 6, and 7, and typically allows up to 25 addressable devices between isolators.
With its durable design, low current draw, and UL and EN-54 certifications, the ISO-X module provides high reliability, electrical noise immunity, and long service life — making it a trusted choice for modern fire detection and alarm systems.
Key Features
– Automatically isolates shorted wiring sections on the SLC loop
– Auto-reset function restores system once fault is cleared
– LED indicator for normal and fault status
– No external power required; powered directly from SLC loop
– Supports wiring styles 4, 6, and 7
– Allows up to 25 devices between isolators
– High immunity to electrical noise and RFI interference
– Compact, lightweight design for easy mounting
– UL and EN-54 certified for global fire-safety standards
– Suitable for commercial, industrial, and institutional applications
Technical Specifications
– Operating Voltage: 15 to 32 VDC (peak)
– Standby Current: approx. 450 µA
– Current Draw (during isolation): approx. 17 mA
– Operating Temperature: 0 °C to 49 °C
– Humidity Range: 10% to 93% RH (non-condensing)
– Dimensions: 11.4 cm × 11.4 cm × 0.6 cm
– Mounting: standard 4 inch square junction box
– Weight: approx. 150 g
– Certifications: UL Listed, EN-54 Compliant
– Brand: Notifier (Honeywell Group)
– Origin: USA
Applications
The ISO-X fault isolator is widely used in:
– Commercial buildings and offices
– Manufacturing and industrial facilities
– Hospitals and educational institutions
– Shopping malls, hotels, and public infrastructure projects
– Any large addressable fire alarm network requiring SLC loop protection
Benefits
– Protects the entire system from short-circuit failure
– Reduces downtime and maintenance cost
– Ensures compliance with international safety codes
About Lixon Power Project Pvt Ltd
Based in Noida, Delhi NCR, Lixon Power Project Pvt Ltd is a leading distributor and project integrator for Notifier, Honeywell, GST, Morley, and other global fire-safety brands. We provide genuine equipment and complete SITC (Supply, Installation, Testing, and Commissioning) services for projects across India and overseas. Our engineering team ensures that every system delivered meets UL, EN-54, and NFPA standards for quality and safety.
Model: ISO-X Brand: Notifier Supplier: Lixon Power Project Pvt Ltd, Noida, Delhi NCR, India
Get Latest Price
| Power Supply | 24 VDC |
| Monitoring Parameters | module |
| Brand | simplex |
| Humidity | 10% to 93% RH, non-condensing |
| Display Type | Analog |
| Model Name/Number | Simplex 4090-9116 Addressable IDNet Communications Isolator |
| Dimensions Mm | 105 mm × 105 mm × 35 mm (≈ 4⅛″ H × 4⅛″ W × 1⅜″ D) |
| Operating Temperature | 0 °C to +49 °C |
| Phase | Single Phase |
| Certifications & Listings | UL Listed (standard 864), ULC, CSFM, MEA (NYC) Acceptance |
Brand: Simplex (Tyco / Johnson Controls)
Model No.: 4090-9116
Product Type: Addressable IDNet Communications Isolator Module
Function: Dual-port, bi-directional short-circuit isolator for IDNet communication lines; automatically isolates sections if a short occurs; can also be manually isolated from the fire panel for diagnostics
Compatible Panels / Protocols: Works with Simplex 4008, 4100ES, 4100U, 4007ES, 4010ES panels using IDNet, IDNet+, IDNet 1+, IDNet 2, IDNet 2+2 output loops
Operating Power Load: One unit load from the IDNet signaling line circuit
Wiring Terminals: In/out ports; supports 14-18 AWG wiring (approx. 0.82 mm² to 2.08 mm²)
Mounting: Fits in standard 4-inch (102 mm) square electrical box; optional adapter plates available for larger boxes to accommodate LED viewing covers
LED Indicator: Visible status LED that flashes to indicate communications; some covers allow LED viewing without removing module
Wiring Distances & Resistance Limits:
• Up to 2500 ft (≈ 762 m) from the panel for a single run
• Up to 10 000 ft (≈ 3048 m) total loop distance including T-taps
• Maximum line resistance between panel and isolator or between isolators: 10 Ω
Operating Temperature Range: 0 °C to +49 °C
Operating Humidity: 10% to 93% RH, non-condensing
Dimensions: ~105 mm × 105 mm × 35 mm (≈ 4⅛″ H × 4⅛″ W × 1⅜″ D)
Housing / Finish: Black thermoplastic body with metal mounting plate
Certifications & Listings: UL Listed (standard 864), ULC, CSFM, MEA (NYC) Acceptance
Shubham Dubey (CEO AND FOUNDER)
Lixon Power Project Private Limited
A-36 Sector 63